Case:
The server is a RAID5 composed of 5 SCSI hard disks.When the customer said that the server was running normally, there were two plates on the red light, and the system could not start after restarting.Data recovery companies hope to do data recovery.
Solution:
The engineer was tested and found that the 5th plate of the server was damaged, and there were a lot of bad sectors on the No. 0 plate.The engineer preferred to use a computer micro -control opening machine in the 100 -level dust purification room to open the market, and then replaced the magnetic head and used professional tools to correct the magnetic head error.Then use professional software mirror data on the data in the market 2.Analysis and calculation through professional software, re -virtual RAID, and export data.For databases for offset calculation, repair, import the database, run successfully, successfully restore server data.