Two Seagate ST3250310NS250GB enterprise hard disk RAID1 data recovery

Case:
A customer’s original two Higher ST3250310NS 250GB enterprise version of the hard block, set the RAID1 configuration. After the host board was burned a few days ago, after the other motherboard was replaced, the HDD could not be read for a period of time.Therefore, data recovery companies perform data recovery.

Solution:
Data recovery company engineers found that after the test, the No. 1 hard block fault problem, there were a large number of magnetic areas in front of the hard block that could not read damage. The No. 2 hard block was a single piece, two magnetic heads, and No. 1 magnetic head fault problems. It was necessary to make it.Opening data recovery processing, because the customer sets RAID1, it is recommended to give priority to the data recovery of the bad orbit of the minor fault. After the data is restored, the customer accepts the acceptance of the information and successfully completes the data recovery case of this RAID1.